shaft end of a HYDAC axial piston pump cannot be avoided,
please consult us already at the project design stage. This
particularly applies to the direct connection (flying storage)
of traction mechanisms such as for example drive belts or
chains to the shaft end.
according to EN 10305/C or hoses with suitable pressure
resistance must be used. The pipes must be deburred,
and feature a specific displacement flow of 10 cm3/rotation to 560 cm3/rotation.
The installation of the hydraulic assembly must be performed
according to the wire and piping diagram and according to the
device-specific installation instruction as well as the technical
pumps must be prevented. If, for specific drive technique
hydraulic unit. Do not plug or close finished pipes with
cleaning cloths but rather with plastic film or tape.
Never usecleaning wool.
data sheets and installation drawings.
If electro-hydraulic circuits are performed, it must be observed
that the prescribed electrical values are adhered to and e.g.
the device has the prescribed voltage.
For the hydraulic pipes, seamless precision steel pipes
a co-axial connection to a drive system, i.e. for a connection
without radial or angle offset between driving and driven shafts.
See the technical data sheet, the installation diagram or
washed out and blown through. Scaled or rusted pipes must
be pickled and then neutralised; brush out decontaminated
hoses and rinse.
Cleanliness is the priority during installation of the entire
the catalogue for the relevant permissible values of the
transmitted shaft torques and the acting axial forces.
Radial forces on the shaft end of the HYDAC axial piston
General information on the mechanical connection
The mechanical connection of a HYDAC axial piston pump to
the drive system is performed via its housing flange and the
shaft end of the primary drive.
HYDAC axial piston pumps are designed as plug on drives for
HYDAC axial piston pumps for open circuit in swash plate
design are available in the pressure ranges medium and high,
reasons or construction considerations, radial forces on the
德國賀德克軸流式活塞泵安裝要求,VD5C.0